- Surgical Instruments[10]
- Physical Therapy Equipments[5]
- Ambulance[1]
- Medical Consumables[3]
- Special Transportation[1]
- Emergency & Clinics Apparatus[7]
- Clinical Analytical Instruments[10]
- Radiology Equipments & Accessories[10]
- Ultrasonic[10]
- Body Fluid-Processing & Circulation Devices[10]
- Dental Equipments[10]
- Sterilization Equipments[10]
- General Assay & Diagnostic Apparatus[5]
- Multi-Functional Beauty Equipment[1]
- Microscopes[3]
- Other Security & Protection Products[1]
- Hospital Chairs[1]
- Hospital Beds[7]
- Weighing Scales[1]
- Veterinary Instrument[4]
- Other Lab Supplies[8]
- Laboratory Thermostatic Devices[1]
- Laboratory Furniture[2]
- PH Meters[5]
- Testing Equipment[4]
- Water Treatment[1]
- Other Analysis Instruments[1]
- Software[1]
- Contact Person : Mr. Dong Jonathan
- Company Name : Anjue Medical Equipment Co., Ltd.
- Tel : 86-556-5836185
- Fax : 86-0556-5836179
- Address : Anhui,Anqing,No.22-23, B8#,Gangcai Dashichang, Anqing, Anhui, China
- Country/Region : China
Dental Digital Panoramic X-ray Machine AJ-DR6/ dental x-ray
Digital Panoramic High Frequency DR X-ray Machine AJ-DR6
Panoramic Parameters
Panoramic | Ceph | |
Focus film distance | 51cm | 158cm |
Time of exposure | 19s | mAs from 2 to 35(12 feet) Normal position |
Functional items | Adult (19 s) Children (16 s) Left side (10 s) Right side (10 s) Middle (10 s ) Mouth open and close TMJ (4*3.2s) Frontal Teeth (12 s) Frontal Sinuses(18 s) | Side face With soft tissued filter |
Cooling and time out | Automatically controlled At most 6 min | Automatically controlled At most 60s |
Film dimensions | 15*30cm flat box | 18*24cm |
X-ray Parameters
Power Supply: 220V,50/60Hz,10A (It can be adjusted as customer’s require.)
Mains Resistance: <1.5ohm at 220 V
X-ray generator: High frequency dc at 20 kHz
Anodic Voltage:60-86 kV, Constant Potential
Anodic Current:4-10 mA, Direct Current
Focus size:0.5*0.5mm
Inherent Filtration:2.5 mm Al
Column Height:230cm
Displacement :90 cm,from 90 to 180 cm
Vertical Movement: Manual Adjustment
Patient Positioning: Manual Carriage Adjustment
Centering Light Lateral
Centering Chin rest
Reference with bite wing
Imaging Parameters of Digital Sensor ipan:
Color Depth | 12bits (4096gray scale) |
Pixel size | 96 micrometer |
Resolution | 4lp/mm |
Scan Time | 10–20sec(depending on host machine) |