Anjue Medical Equipment Co., Ltd.
Products
Contact Us
  • Contact Person : Mr. Dong Jonathan
  • Company Name : Anjue Medical Equipment Co., Ltd.
  • Tel : 86-556-5836185
  • Fax : 86-0556-5836179
  • Address : Anhui,Anqing,No.22-23, B8#,Gangcai Dashichang, Anqing, Anhui, China
  • Country/Region : China

Electronic Spirometer / Pulmonary Function Analyzer MSA99

Electronic Spirometer / Pulmonary Function Analyzer MSA99
Product Detailed
Pulmonary Function Analyzer: 1.FVC: per second, 25s, measuring 3 2.Flow velocity range: 0 ~ 14L / s Type: Spirometer

Electronic Spirometer / Pulmonary Function Analyzer MSA99

 

 

*The portable pulmonary function measurement instrument can be used to measure vital capacity (VC), forced vital capacity (FVC), Maximum Ventilation Volume (MVV). Measurement algorithm refers to the ITS, ERS standards of the American Thoracic Society (ATS)

 

*Adopting pressure-flow sensor, sensitive, precise, easy to launder, clean and durable

*All parameters can be displayed on the oversized screen(320x240), built-in memory can store maximum 300 cases of patient measurement results

 

*The instrument can calibrate automatically, all English operation, more convenient to operate

 

*110mm thermal printer built-in, can print out a clear clinical report, predicted value, measured value

 

*Measurement of breathing time: VC time 50 seconds, FVC measuring time 25 seconds, MVV time 12 seconds, in favor of the coordination between patients and the device

 

*Compact and flexible

 

 

Items

Technique specification

Display Screen

Diagonal line  5.7inches

Monochrome LCD

Resolution 320*240

Control

Standard: UTILITY KEY,SVC KEY,FVC KEY,MVV KEY,PRINT KEY,10WORDS KEY, START KEY,STOP KEY

Light alarm

Measurement means

Flow velocity detection: pressure gradient pneumatic flow sensor

Capacity detection: flow velocity integral

measuring range

Capacity range: 0L ~ 9L

Flow velocity range: 0 ~ 14L / s

measurement accuracy 

Capacity:

0L ~ 1.6L (± 50ml) 

 6L ~ 9L (± 3%) 

Flow rate: 5% or 0.2L / s 

Respiratory rate:

4 / 20 ~ / min (± 1 / min) 

 20 / 60 / min (error: ± 5%) 

measuring time limit and degree

Vital capacity: every 50s, measuring 3 

 FVC: per second, 25s, measuring 3 

 The maximum ventilation volume: every 12 seconds, measuring 3 

Paper Recorder

Method: dot matrix

Level Resolution Ration: 8 d/mmspeed 25mm/s

Uprightness Resolution Ration: 8 d/mm

Wave Channels: 1

Paper Width: 110mm1.97inches

Paper Length: 15m100inches

Formfeed Speed: 12.5,25 and 50mm/s±2

Power supply

AC: 100V~240V

DC: rechargeable Nickel-metal hydride (NI-MH), 14.4-volt, 1.8 amp hour

Fuse

100V~240V ACF2A250V,5×20mm

Safety classification

IEC60601-1 class I, type CF

 

 

Electronic Spirometer / Pulmonary Function Analyzer MSA99



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.